InBody devices use a method called Bio-electrical Impedance Analysis (BIA) to measure body composition. This divides your weight into different components, e.g., lean body mass and fat mass are utilized in the assessment of health and nutrition.
Measuring impedance with electrodes creates contact resistance.
InBody accounts for this by strategically placing electrodes to accurately measure.
InBody uses multiple currents and varying frequencies.
No empirical estimations are used to calculate body composition.
InBody measures impedance independently, so results are not affected by age, ethnicity, or gender.
One major problem with the one-cylinder method is the lack of a torso measurement.
The torso has the lowest length and highest cross-section area.
This results in a very low impedance (10-40 ohms).
However, the trunk comprises about 50% of an individual�s lean body mass (LBM).
In the whole-body impedance measurement, the torso impedance is ignored and so changes the body torso impedance.
If the body torso is not measured separately then the impedance of the torso could be overlooked.
Because the body torso contains more water and muscles than the limbs, 1 ohm of torso impedance and 1 ohm of limb impedance can be completely different.
A difference of even 1-2 ohms can lead to a significant error in the determination of TBW.
Some BIA devices only measure the impedance values of two cylinders and estimate the rest.
Some BIA scales only measure the legs.
For BIA handheld devices, only the arms are measured.
Some devices say they measure the whole body when they only measure one arm, one leg, and estimate the rest.
When using a BIA device, find one that actually measures the torso and measures it separately.
Otherwise, the estimations can lead to large errors.
InBody devices do not estimate through Direct Segmental Multi-frequency BIA, which in simpler terms, which means that each segment of the body right arm, left arm, torso, right leg, left leg are measured separately.
In 1969, Hoffer experimented to prove that total body water and biological impedance were highly interconnected. This meant that impedance measurement could be used to determine total body water.
He showed the squared value of height divided by impedance was highly correlated with total body water.
He took impedance measurements of the right half of the body. These included the right arm, torso, and right leg.
The equation he proved is the impedance index used in Bioelectrical analysis today.
In 1979, RJL Systems brought the impedance meter and the BIA method began.
The device measured impedance through attachment of electrodes on the back of the right hand and on top of the right foot. A current of 50kHz was run through the right half of the body.
Before this, body composition could only be measured with calipers or underwater weighing.
These techniques had to be carried out by skilled people and was not easy.
Only specific types of patients were able to benefit from them, as well.
However, this was fast, less expensive and less intrusive. Thus, body composition analysts, nutritionists, and medical experts started using BIA technology.
Lukaski, Segal and other scholars are the ones that accelerated the evolution of BIA.
Their studies proved that BIA had a high correlation with top standard methods, e.g., Underwater Weighing and DEXA.
However, there were technical limitations with BIA which surfaced towards the end of 1980s.
A common limitation was that BIA would assumed the human body was a cylinder shape and so only used a single frequency of 50 kHz.
Through research, various equations evolved (along with the impedance index). This complemented the technical limitation of BIA and was able to achieve greater accuracy for patients of different age, gender etc.
Empirical data is defined, as knowledge acquired by means of observation or experimentation.
By collecting data on a sample population that (hopefully) represents the variance of the entire population, researchers attempt to derive trends that may be used to predict outcomes.
In body composition, researchers identify these trends in muscle and fat mass; they use this data to predict body composition based on specific variables (age, gender, ethnicity, etc.)
Although empirical estimations could give you an accurate estimate of a general user�s body composition, there are significant problems when they are used for medical purposes.
Suppose there is a device that uses empirical equations to calculate TBW.
And there are two individuals who have same amount of lean body mass, however, one is 30 years old and the other is 40 years old.
Even though they have the same amount of LBM, the empirical equation will calculate that both will have 0.8 L difference in their TBW. This only because of age, which is not fair or accurate.
Because of technological limitations, BIA devices turned into home devices instead of hospital devices.
Then Japanese manufacturers released a variety of BIA body composition devices that the general public could easily use.
Some measured the impedance between two feet while standing on a scale. Others would hold the device and then measure the impedance between the hands.
Since the torso makes up 50% of lean body mass, Kushner emphasized measuring the impedance of the torso separately would be very significant.
Measuring total impedance alone is not sufficient. However, when all five parts are measured separately at different frequencies, then a distinction between extracellular water and intracellular water can be made.
In 1996, Dr. Kichul Cha, a bioengineer from Harvard Medical School, develops the first 8-point electrode system with direct segmental analysis, which measures impedance for the five cylinders of the body at multiple frequencies.
This allows separate checking of torso impedance.
With this technology highly accurate results, without using empirical data, were able to be yielded.
InBody body composition analyzers became precision based medical devices. Impedance values for all of the body’s cylinders can be found on the InBody Result Sheet.
Many BIA products today provide muscle mass for each section of the body.
However, you can see the impedance values of all five parts of the body with the use of both high and low frequencies.
One-Compartment Water Model The one-compartment water model accounts for Total Body Water (TBW).
Total Body Water is the sum of Intracellular Water plus Extracellular Water and is wholly contained within Fat-Free Mass.
Normally, about 73% of Fat-Free Mass is water.
This model is handy for evaluating basic hydration status of patients.
This model is often used for the assessment of fluid balance associated with the treatment of conditions in a clinical setting.
NOTE: Exercise is important in BIA because weight loss from dieting alone is comprised of 45 percent fat-free mass and 55 percent fat mass per pound. Exercise can alter this ratio to 25 percent fat-free mass and 75 percent fat mass.
Professional Scope of Practice *
The information herein on "Bioelectrical Impedance Analysis Application | El Paso, Tx." is not intended to replace a one-on-one relationship with a qualified health care professional or licensed physician and is not medical advice. We encourage you to make healthcare decisions based on your research and partnership with a qualified healthcare professional.
Blog Information & Scope Discussions
Our information scope is limited to Chiropractic, musculoskeletal, physical medicines, wellness, contributing etiological viscerosomatic disturbances within clinical presentations, associated somatovisceral reflex clinical dynamics, subluxation complexes, sensitive health issues, and/or functional medicine articles, topics, and discussions.
We provide and present clinical collaboration with specialists from various disciplines. Each specialist is governed by their professional scope of practice and their jurisdiction of licensure. We use functional health & wellness protocols to treat and support care for the injuries or disorders of the musculoskeletal system.
Our videos, posts, topics, subjects, and insights cover clinical matters, issues, and topics that relate to and directly or indirectly support our clinical scope of practice.*
Our office has reasonably attempted to provide supportive citations and has identified the relevant research study or studies supporting our posts. We provide copies of supporting research studies available to regulatory boards and the public upon request.
We understand that we cover matters that require an additional explanation of how it may assist in a particular care plan or treatment protocol; therefore, to further discuss the subject matter above, please feel free to ask Dr. Alex Jimenez, DC, or contact us at 915-850-0900.
We are here to help you and your family.
Blessings
Dr. Alex Jimenez DC, MSACP, RN*, CCST, IFMCP*, CIFM*, ATN*
email: coach@elpasofunctionalmedicine.com
Licensed as a Doctor of Chiropractic (DC) in Texas & New Mexico*
Texas DC License # TX5807, New Mexico DC License # NM-DC2182
Licensed as a Registered Nurse (RN*) in Florida
Florida License RN License # RN9617241 (Control No. 3558029)
Compact Status: Multi-State License: Authorized to Practice in 40 States*
Dr. Alex Jimenez DC, MSACP, RN* CIFM*, IFMCP*, ATN*, CCST
My Digital Business Card
Stress on the lower back during pregnancy often leads to back (upper, middle, lower), sciatica,… Read More
Can melatonin help many individuals dealing with sleep issues and help them stay asleep longer… Read More
For older individuals looking for a workout that can help improve overall fitness, can kettlebell… Read More
Can choosing the right pillow help many individuals with neck pain get a full night's… Read More
What is the recommended way to choose a mattress for individuals with back pain? … Read More
Can non-surgical treatments help individuals with piriformis syndrome reduce referred sciatica pain and help restore… Read More